Installation Instructions
for a “Single” gate...
THE FROG-S KIT CONSISTS OF:
1 X UNDERGROUND FOUNDATION CASINGS
1 X UNDERGROUND GATE MOTORS
1 X CONTROL PANEL
1 X RADIO FREQUENCY CARD
1 X TUNED ANTENNA
2 X REMOTE CONTROL TRANSMITTERS
1 X PAIR SAFETY BEAMS
0115 921 0430
Vista de página 0
1 2 3 4 5 6 ... 31 32

Resumo do Conteúdo

Página 1 - FROG KIT

FROG KITCAME UNITED KINGDOM LTDORCHARD PARK INDUSTRIAL ESTATETOWN STREET, SANDIACRE,NOTTINGHAM, NG10 5BPTEL: 0115 921 0430FAX: 0115 921 0431INTERNET -

Página 2 - INTRODUCTION

92.2 - Wiring the MotorTHE FROG MOTOR ALWAYS COMES PREWIRED AND THE CONNECTIONS TOTHE MOTOR SHOULD BE MADE IN THE JUNCTION BOXES AT THE BASE OFTHE GAT

Página 3 - CONTENTS

10ZA42.3 - Wiring in the Safety PhotocellsSAFETY BEAMS SHOULD BE FITTED APPROXIMATELY15 INCHES FROM GROUND LEVELCONTROL PANEL10 11

Página 4 - FOR CONCRETE

2.5 - Wiring in the Tuned Antenna2.6 - Coding the Remote Controls1. REMOVE THE BATTERY COVER & CASING OF THE REMOTE CONTROLHANDSET TO REVEAL THE D

Página 5 - 1.2 - Basic Cable Layout

END OF INSTALLATIONSTAGE 2BEFORE STARTING STAGE 3 -Commissioning the Control PanelPLEASE CHECK THAT YOU HAVE CORRECTLY:Ref Page1. FITTING THE CONTRO

Página 6 - 1.5 - Hanging the Gate

STAGE 3COMMISSIONING THE CONTROL PANEL3.1 - Initial Wiring & Control Panel Setup131. CONNECT POWER TERMINALS L1 - L2AND A SUITABLE EARTH (L2 BEING

Página 7 - 1.6 - Fitting the Gate Lock

3.2 - Opening & Closing the Gate2. ONCE YOU HAVE PROVED THEMOTOR DIRECTION USETERMINALS 2 & 7 TO OPEN ANDCLOSE THE GATES WITH ATRAILING WIRE O

Página 8

153.3 - Control Panel AdjustmentsTRIMMER TL1. TO SET THE TOTAL RUNNING TIME OF THE MOTORS, ADJUSTPOTENIOMETER TL TO ALLOW THE MOTORS TO RUN FOR A FUR

Página 9 - Fastening screws

3.4 - Automatic Close & Activating Safety PhotocellsFULLY ANTI-CLOCKWISE WILL APPROX. AUTOMATICALLY CLOSE THE GATEAFTER 10 SECONDS AND FULLY CLOCK

Página 10 - 2.2 - Wiring the Motor

173.5 - Programming the Remote Controlsto the Control PanelTo use the remote control system, proceed as follows:A) Turn power OFF and insert AF radio

Página 11 - CONTROL PANEL

PLEASE CHECK THAT YOU HAVE CORRECTLY:Ref Page1. SET POWER SETTING, INSERTED MOTORCAPACITORS, SET DIPSWITCHES FORCOMMISSIONING, ENSURE WIRE LINKIS F

Página 12 - IS ADEQUATELY EARTHED

THESE INSTRUCTIONS WILL SHOW YOU HOW TO INSTALLA FROG UNDERGROUND GATE KIT TO A SINGLE GATE.PLEASE READ THESE INSTRUCTIONS AND DIAGRAMSCAREFULLY BEFOR

Página 13 - END OF INSTALLATION

4. TROUBLESHOOTING GUIDEA MULTIMETER WILL BE NEEDED PROBLEM SOLUTIONGATE WILL NOT RESPONDWHEN GIVEN A COMMAND 1. CHECK POWER SUPPLY TO THECO

Página 14 -

PROBLEMSOLUTION 1. AF FREQUENCY CARD NOT FITTED TOCONTROL PANEL. 2. REMOTE CONTROL HAS NOT BEENPROGRAMMED INTO THE CONTROLPANEL. 3. REMOTE CONTROL

Página 15

215. TECHNICAL INFORMATION5.1 - Technical Specification* Can be adjusted using CAME control panels GEARMOTOR WEIGHT POWER CURRENT

Página 16 - TRIMMER TL

5.4 - Motor Torque SettingsTo vary the motor torque, move the indicated sp

Página 17 - 6 O’CLOCK

5.5 - ZA5 Control Panel DescriptionDescription of Control Panel:The ZA5 control board is suitable for controlling one automation of ATI, FERNIand FROG

Página 18

UNDERGROUNDGATE MOTORUNDERGROUND FOUNDATIONCASING WITH PIVOT ARM.TUNED ANTENNAFig 261 CONTROL PANEL1 FREQUENCY CARD1 PAIR SAFETYBEAMS2 REMOTE CONTROLT

Página 19

5.6 - ZA5 Wiring Diagram25Terminals 1 and 2, 2 and C1 are normally closed circuits and ifthey are not used they must be linkedCo-axial cable230V A/CSi

Página 20 - 4. TROUBLESHOOTING GUIDE

26 5.7 - Control Panel AdjustmentsFig 27Trimmer T.L. - Adjustment of opera

Página 21 - SOLUTION

275.8 - Electrical ConnectionsL1 L2 U V W E1 ES 10 11 1 2 3 5 7 C1230V (a.c.) power input230V (a.c.) single-phas

Página 22 - 5. TECHNICAL INFORMATION

5.10 - Re-Handing the Frog MotorsSCREW THE M10 X 100MM BOLT (A) AND THE M10 NUT (B) INTO THEMOTOR TRANSMISSION ARM AS SHOWN IN FIGURE ABOVE. FOR R/HMO

Página 23 - 5.4 - Motor Torque Settings

INSTALLATION INSTRUCTIONSCONTENTS1) Stage 1:- Civil & Mechanical Section Page1.1 INSTALLATION OF THE FOUNDATION 31.2 BASIC CABLE LAYOUT 41.3 L

Página 26 - 5.6 - ZA5 Wiring Diagram

6. CONTACT INFORMATIONTHIS INSTALLATION WAS COMPLETED BY:...NAME...

Página 27

67mm3mm160mm100mm60mmDUCTING FORMOTOR WIRESHEEL OF CASINGSOAK AWAY3STAGE 1CIVIL & MECHANICAL SECTION1.1 - Installation of Foundation CasingTHE UND

Página 28 - 5.8 - Electrical Connections

1.2 - Basic Cable LayoutTHIS DIAGRAM DETAILS THE BASIC CABLE LAYOUT FORA SINGLE MOTOR.THE POWER SUPPLY TO THE CONTROL PANEL SHOULD BE LIVE ANDPROTECTE

Página 29

90°51.4 - Installing the MotorsINSERT THE MOTORS ONTO THE STUDS IN THE CASING. IF THE GATESARE HUNG BETWEEN THE POSTS AND THE GATES OPEN INWARDS THEM

Página 30

61.6 - Fitting the Gate LockSecure the unlocking device to the FROG shoe with the 4 allen bolts provided.To release the gate, raise the protective cap

Página 31

7BEFORE STARTING STAGE 2 - Wiring & ElectricalPLEASE CHECK THAT YOU HAVE CORRECTLY:Ref Page1. INSTALLED THE FOUNDATION CASING 1.1 32. PREPARED T

Página 32 - 6. CONTACT INFORMATION

STAGE 2 - WIRING & ELECTRICAL2.1 - Fitting the Control Panel in the Casing8